通风设备网
诚敬信息技术

浅谈轴流风机的优缺点和故障诊断

   日期:2012-06-21     浏览:2022    评论:0    
摘要:大型火力发电机组的设备选型一般将动叶可调轴流风机选择为锅炉送风机,动叶可调轴流风机在运行中具有操作方便、调节性能好等优点,但其核心机构均为动调执行机构,其结构精密,对装调、维护均有较高要求,本文试图分析改型风机在实际运用中的常见异常并提出处理建议。

  Abstract: large-scale firepower aircrew equipment selection general will move leaves adjustable axial flow fans choice for boiler, dynamic leaf blowers adjustable axial flow fan in operation is easy to operate, regulation performance advantages, but its core agencies have to move the actuators, the precise structure, to assembly and adjustment and maintenance are higher demand, this paper attempts to analyze the retrofit fan in the practical application of the common problems and propose.

  关键词:动叶可调风机;动叶;异常分析;故障处理

  Key words: the move leaves adjustable fan; move abnormal; failure analysis; processing

  1 文章快照

  动叶可调风机反馈不正常的原因检修人员和厂家人员共同检查,均发现属于控制头控制失灵,即风机在旋转过程中叶片突然向全开或全关的方向滑去,失去调节能力,从而使风机的运行电流突然增大或缩小,风机不能正常运行。而保证风机旋转中正常运行、叶片稳定在合适角度的机构是反馈系统,在风机控制头末端装有1只反馈球轴承,球轴承损坏将导致反馈杆失去定位,不能正常带动错油阀的外套移动,此外,用于固定反馈轴承的螺母,由于风机的振动等原因造成该螺母松脱,也会导致反馈杆失灵,反馈杆不能带动错油阀的外套移动,也就不能将调节系统的进油口封住,风机叶片只能向全开或全关的方向滑去,最终靠机械限位稳定在极限位置。解决方案是逢停必检,在机组停运时,安排检查送风机控制头反馈轴承及其固定螺母,发现异常及时处理。注明(动叶可调风机执行器选型如德国欧码执行器全开全关是不超过53秒)。

  1.1 两级动叶可调一次风机和动可调叶送风机常见故障处理

  (1) 轴承箱漏油问题轴承箱漏油一般不会影响设备安全运行,只会对现场文明生产造成影响,在黄岛电厂的一次风机和鲁北电厂的送风机在生产过程中已经先后发生过几次,根本原因是轴承箱端部密封使用的是骨架油封,长周期运行后发生橡胶龟裂等异常造成泄漏,目前暂无更好的密封方法解决(密封选择德国前西德设计生产),正常运行时。

  (2) 在保证风机安全的前提下,适当降低润滑油压(根据经验一般在0.28-0.30Mpa即可维持运行)以减少泄漏量,此外,风机漏油位置相对固定,一般在风机出口膨胀节处,为保证现场文明生产,可考虑安装专用接油装置。

  (3)油质问题送风机控制头结构决定了其内部间隙非常小,油质不好造成油系统污染,影响风机正常调节,而送风机安装在电除尘器附近,灰尘多、污染大,因此,应加强送风机油质检验,建议定期化验和安排润滑油过滤和更换。

  (4) 动叶可调轴流送风机属于锅炉辅机中比较精密设备,安装检修要求高,熟悉送风机液控部分结构有利于加强设备检修维护,保证检修成功率。

  1.2轴流风机动叶调节原理(TLT结构)

  (1) 轴流动叶可调一次风机和送风机利用动叶安装角的变化,使风机的性能曲线移位。性能曲线与不同的动叶安装角与风道性能曲线,可以得出一系列的工作点。若需要流量及压头增大,只需增大动叶安装角;反之只需减少动叶安装角。

  (2) 轴流送风机的动叶调节,调节效率高,而且又能使调节后的风机处于高效率区内工作。采用动叶调节的轴流送风机还可以避免在小流量工况下落在不稳定工况区内。轴流送风机动叶调节使风机结构复杂,调节装置要求较高,制造精度要求亦高。

 
 
更多>同类行业资讯
0相关评论